U-CTXUHR Computed Tomography Scanner (MILabs, The Netherlands)
The U-CTXUHR computed tomography system by MILabs is one of the most advanced devices for preclinical computed tomography (micro-CT). It has been designed for both in vivo and ex vivo studies using small laboratory animals (mice, rats, guinea pigs, isolated tissues, bones).
The system offers advanced diagnostic capabilities, including dynamic contrast-enhanced CT imaging (DCE) using single- or dual-energy scans, ultra-fast fluoroscopic imaging at up to 66 frames per second, DEXA scanning (spiral and circular imaging), virtual endoscopy, and cardiac and respiratory gating (4D system) – if required, without sensors, enabling simultaneous imaging of multiple animals.
It is characterised by ultra-high image resolution, with reconstruction down to 2.4 μm using a dedicated holder for ex vivo samples. The micro-CT system is fast and capable of performing whole-body mouse scans in just 5 seconds at very low radiation doses (below 2 mGy for the whole body).
For analysis of reconstructed images, the PMOD software has been acquired, enabling evaluation of medical parameters, including quantitative image analysis. It supports multimodal image fusion, three-dimensional visualisation, and geometric modelling of acquired data.
PMOD Software Version X (PMOD Technologies Ltd, Bruker Corporation)
- PMOD is an advanced tool for quantitative analysis of imaging data from medical imaging modalities such as CT, SPECT, and MRI. The software is widely used in both preclinical and clinical research, particularly in pharmacology, neurology, cardiology, and oncology.
- Main functionalities:
- image co-registration and segmentation
- 4D data processing (time + space)
- ROI (region of interest) and VOI (volume of interest) tools
- support for multiple data formats (DICOM, ECAT, Analyze, NIfTI).
The equipment available in the Laboratory enables:
- In vivo imaging – live animals (mouse, rat, guinea pig) under inhalation anaesthesia (anaesthesia system integrated with the scanner) or general anaesthesia administered intravenously or intraperitoneally prior to imaging.
- Ex vivo imaging – isolated body parts, organs, and bones examined immediately after euthanasia or previously frozen (provided that freezing does not adversely affect the analysed structure). In this case, the material may also originate from larger animals.
EXAMPLES OF STUDIES PERFORMED USING U-CTXUHR
Analysis of alveolar bone loss in the mouse maxilla following induction of periodontal inflammation: Benedyk-Machaczka M, et al. Preclinical Validation of MIN-T: A Novel Controlled-Released Formulation for the Adjunctive Local Application of Minicycline in Periodontitis. Antibiotics (Basel). 2024 Oct 28;13(11):1012.

Analysis of bone deformation and erosion in the hind paws, calcaneus, sacroiliac joints, and caudal vertebrae in SKG mice with induced spondyloarthropathy: Czepiel M, et al. Monoclonal Antibodies Against Vascular Endothelial Growth Factor A (VEGF-A) Reduce Synovitis, Bone Damage, and Osteogenesis in an SKG Mouse Model of Spondyloarthritis. J Immunol Res. 2025 May 30;2025:8870895.

BOOKINGS
Imaging using the computed tomography scanner is performed exclusively by authorised personnel. An exception is made for users who routinely perform CT imaging as part of their research and have received appropriate training.
Reservations for equipment use and imaging time should be made by telephone or email using the CONTACT details provided below.
In the event of changes to research plans, reservations must be cancelled no later than 7 days prior to the scheduled imaging session.
PRICING
- • Staff of the Faculty of Biochemistry, Biophysics and Biotechnology, Jagiellonian University – PLN/hour
- • Staff of other units of Jagiellonian University – PLN/hour.
DATA MANAGMENT
Raw imaging data, reconstructed data, and processed data obtained using PMOD software will be stored in a cloud storage service for a period of 2 months. Users will be granted access via a shared link.
Files stored in the cloud constitute the only copy retained by the Imaging Laboratory. Their deletion will result in permanent loss of data from the hard drive of the computer connected to the scanner. Additionally, data may be downloaded immediately after the study onto a user’s own storage device (e.g. USB drive).
ACKNOWLEDGMENTS
When publishing or presenting results obtained using the Small Animal Computed Tomography Laboratory, users are kindly requested to include the following statement in the Acknowledgements section:
The examination was performed using the U-CTXUHR computed tomography scanner at the Small Animal Computed Tomography Laboratory, an integral imaging facility at the Faculty of Biochemistry, Biophysics, and Biotechnology of Jagiellonian University.
Including this information helps secure continued funding and maintain access to high-quality CT imaging services for the scientific community.
Please send information about published results (DOI number) to: malgorzata.benedyk@uj.edu.pl.
COORDINATOR: Dr Małgorzata Benedyk-Machaczka, Department of Microbiology
- tel.: +48 12 664 61 10
- e-mail: malgorzata.benedyk@uj.edu.pl
OPERATOR: Dr Izabela Ciastoń, Department of Microbiology
- tel.: +48 12 664 61 29
- e-mail: izabela.ciaston@uj.edu.pl