The Bioimaging Laboratory is part of the Biological Structure Imaging and Spatial Transcriptomics Facility, a unit established to provide imaging and analytical services for organisational units of Jagiellonian University as well as external entities. The Laboratory offers advanced microscopy measurements using the STEDYCON (Abberior) and Stellaris 5 (Leica) confocal imaging systems.  

The Laboratory's equipment is available on a fee-for-service basis to all staff members of the Faculty of Biochemistry, Biophysics and Biotechnology, other units of Jagiellonian University, and, with certain exceptions, external users. 

STEDYCON Microscope (Abberior)*

Location: Level 02, Room 4.02.7B
 
The STEDYCON system combines confocal microscopy with STED nanoscopy, enabling image acquisition at resolutions of up to 30 nm. Imaging can also be performed in confocal mode only, reducing requirements regarding fluorophore stability and brightness. Nevertheless, users should verify that fluorophores are suitable for confocal microscopy and that their fluorescence emission spectra overlap efficiently with the wavelength ranges collected by the available detectors. 
 
Fluorescence Excitation:
  • 405 nm (CW diode laser) 
  • 488 nm, 561 nm, 640 nm (three pulsed diode lasers) 
  • STED laser (775 nm) 
Signal detection is performed using four avalanche photodiodes operating in single-photon counting mode within the following wavelength ranges:
  • 420–480 nm (60 nm bandwidth) 
  • 505–545 nm (40 nm bandwidth) 
  • 575–625 nm (50 nm bandwidth) 
  • 650–700 nm (50 nm bandwidth) 
Available Objectives:
  • UPlanXApo (extended apochromat) 100×/1.45 NA (oil immersion) 
  • UPlanFL (semi-apochromat) N 10×/0.3 NA 
  • UPlanFL (semi-apochromat) 20×/0.5 NA 

STEDYCON Smart Control Software

Image files may be saved in .tiff, .png, and .pdf formats either as raw data or after basic processing (noise reduction, smoothing, scale bars, colour bars, etc.). 
 
Live-Cell Imaging
Microscopy observations may be performed on fixed specimens or live cells using a BL-type incubator with CO₂ control. 
 
Recommendations for STED Microscopy
The Laboratory recommends the use of fluorophores specifically designed for STED microscopy, offering enhanced brightness and photostability. Dyes such as DAPI and Hoechst should be avoided, as they may adversely affect image background quality.
 
Furthermore, both the material and thickness of the substrate supporting the cells may influence image resolution. The recommended cover glass thickness is 0.17 mm, using high-quality optical glass products such as:
  • Hecht-Assistent cover slips 
  • Menzel cover slips 
  • Marienfeld-Superior cover slips 
  • Lab-Tek Chamber Slide System (Thermo Fisher Scientific) 
  • Ibidi µ-Slides and µ-Dishes 
  • MatTek Glass Bottom Dishes 
*The instrument was acquired through the Jagiellonian University Excellence Initiative (ID UJ) and the Priority Research Area BioS subsidy awarded to the Faculty of Biochemistry, Biophysics and Biotechnology. 

INTEGRATED MICROMANIPULATION SYSTEM WITH LEICA STELLARIS CONFOCAL MICROSCOPE

Location: Level 02, Room 4.02.7B
 
The Stellaris system combines a cellular micromanipulation platform with a fluorescence confocal microscope, enabling targeted interventions in the physiology of individual cells. Applications include:
  • precise delivery of biomolecules, markers, and organelles into cells, 
  • exposure of cells to controlled chemical and physical stimuli, 
  • manipulation and isolation of individual cells. 
The integrated imaging system and environmental chamber enable real-time live-cell analyses under transmitted-light and fluorescence conditions, including studies of cellular dynamics and specifically defined cellular regions and organelles. 
 
The system is equipped with the LIGHTNING module, a fully automated adaptive information extraction process that enhances resolution to approximately 120 nm. Owing to rapid image acquisition and low phototoxicity, the module is also suitable for live-cell imaging applications. 
Fluorescence Excitation
  • 405 nm (50 mW) 
  • 488 nm (20 mW) 
  • 561 nm (20 mW) 
  • 638 nm (30 mW) 
Signal detection is performed using Power HyD S spectral detectors, which combine photomultiplier and avalanche photodiode technologies. Detection bandwidth can be adjusted from 5 nm up to the full spectral range, with spectral positioning accuracy of 1 nm. 
 
Available Objectives:
  • Plan semi-apochromat 5×/0.15 NA 
  • Plan semi-apochromat 10×/0.3 NA 
  • Plan semi-apochromat 20×/0.4 NA 
  • Plan apochromat 20×/0.75 NA (multi-immersion: water, glycerol, oil) 
  • Plan apochromat 40×/1.3 NA (oil immersion) 
  • Plan apochromat 63×/1.4 NA (oil immersion) 
Additional equipment:
  • Differential Interference Contrast (DIC/Nomarski) imaging capability 

LAS X Software
Data may be saved in .lif, .tiff, and .png formats as raw or processed files. The software also supports:

  • three-dimensional reconstruction, 
  • image deconvolution, 
  • advanced image analysis workflows. 
Environmental Control
The microscope is equipped with:
  • a temperature-controlled environmental chamber, 
  • a mini-incubator with CO₂ regulation, 
  • an anti-vibration table. 
EPPENDORF MICROMANIPULATION SYSTEM
The microscope is equipped with a comprehensive Eppendorf micromanipulation platform, comprising: 
1. Cellular Micromanipulator
  • Working angle range: 0–90° 
  • Movement speed range: 0–10,000 μm/s 
  • Motorised horizontal rotation from –45° to 90° 
2. Microinjection Micromanipulator
  • Programmable auxiliary functions (minimum of five programmable positions) 
  • Y-axis movement restriction 
  • Upper and lower safety limits preventing capillary breakage 
  • Automated capillary cleaning functions 
  • Step size (computational resolution) below 20 nm 
  • Mechanical adjustment range exceeding 80 mm 
3. Electronic Microinjector
  • Injection volume range: femtolitres to 100 pL 
  • Integrated compressor requiring no external pumps or compressed-air systems 
  • Suitable for reproducible serial microinjections into adherent and suspension cells 
4. Electronic Microinjector
  • Injection volume range: 100 pL to 1 mL 
5. Pneumatic Microinjector
6. Oil Microinjector
7. Piezo-Assisted Micromanipulation Device
 
The Laboratory does not provide capillaries required for micromanipulation experiments. Users are responsible for supplying these consumables. 
 
The system was acquired through the Polish National Research Infrastructure Roadmap programme, financed by the state budget through a targeted grant supporting scientific research infrastructure. 

BOOKINGS

Equipment and imaging time must be reserved using the electronic booking forms (Microsoft Forms). Reservations may be made no earlier than one month and no later than one day before the planned experiment. Access is granted on a first-come, first-served basis. The minimum booking period is one hour. 
PRICING
STEDYCON Microscope
User Category Fee
  • Faculty of Biochemistry, Biophysics and Biotechnology (FBBB) staff PLN 50/hour
  • Staff of other Jagiellonian University units PLN 105.01/hour
  • External users PLN 140 net/hour + 23% VAT
Stellaris 5 Microscope with Micromanipulation System*
User Category Fee:
  • FBBB staff PLN 70/hour
  • Staff of other JU units using project funding (without FBBB overheads) PLN 133.05 net/hour
  • Staff of other JU units PLN 154.06 net/hour
*Due to the funding conditions under which the system was acquired, the equipment cannot be offered commercially to external users. 
 

Should a user need to cancel a reservation, cancellation must be made no later than two hours before the scheduled session. If cancellation occurs after this deadline, or if samples are not delivered for analysis, the user will be charged according to the applicable hourly rate for the reserved instrument. 

ACKNOWLEDGEMENTS

Researchers publishing results obtained using the Bioimaging Laboratory facilities are requested to acknowledge the use of the infrastructure in the Acknowledgements section of their publications. Suggested wording includes: 

Some/All of the optical microscopy experiments (name of the technique and equipment used) were performed at the Bioimaging Laboratory, which serves as an imaging core facility at the Faculty of Biochemistry, Biophysics and Biotechnology, Jagiellonian University.

The purchase of the STEDYCON microscope (Abberior) was supported by a grant from the Priority Research Area BioS under the Strategic Programme Excellence Initiative at Jagiellonian University. 

Such acknowledgements contribute to the continued funding and maintenance of advanced microscopy infrastructure for the scientific community. Authors are kindly requested to send publication details and DOI numbers to: wbbib.bioobrazowanie@uj.edu.pl 

DATA MANAGEMENT

Raw imaging data and any processed datasets generated during experiments are stored in an encrypted cloud-based storage system for a period of three months. Access is provided through secure download links. Transfer of data using USB storage devices is not permitted. 
 
The cloud repository constitutes the only copy maintained by the Laboratory. Once data are removed from cloud storage, they are also deleted from the hard drive of the computer connected to the microscope. 
 
The Laboratory strongly encourages users to deposit datasets in specialised repositories dedicated to microscopy research data, including:
  • Image Data Resource (IDR) 
  • BioImage Archive 

or in general-purpose open repositories such as:

  • Zenodo 
  • BioStudies 
  • RODBUK – the Open Research Data Repository of Kraków Universities. 
All imaging systems operated by the Laboratory generate files containing comprehensive acquisition metadata. 
 
The Laboratory also provides support in the preparation of Data Management Plans (DMPs) related to microscopy data for current and prospective users. Enquiries should be directed to: wbbib.bioobrazowanie@uj.edu.pl 

Laboratory Coordinator: Dr Beata Rysiewicz

  • phone: +48 538 629 891
  • e-mail: wbbib.bioobrazowanie@uj.edu.pl
  • room: pokój 1.01.3 (level 01)

Selected publications presenting results obtained using equipment available at the Bioimaging Laboratory

3D Visualisation of fixed samples​ (Uptake of EVs)

  • Host cell responses to Candida albicans biofilm-derived extracellular vesicles. Kamila Kulig, Ewelina Wronowska, Magdalena Juszczak, Marcin Zawrotniak, Justyna Karkowska-Kuleta, Maria Rapala-Kozik, Frontiers in Cellular and Infection Microbiology; doi: 10.3389/fcimb.2024.1499461

Micromanipulation (Calcein microinjection)

  • Metabolic reprogramming of poly(morpho) nuclear giant cells determines glioblastoma recovery from doxorubicin-induced stress. Maciej Pudełek, Damian Ryszawy, Katarzyna Piwowarczyk, Sławomir Lasota, Zbigniew Madeja, Sylwia Kędracka-Krok and Jarosław Czyż. Journal of Translational Medicine. doi.org/10.1186/s12967-024-05541-9

Imaging of protein recruitment following localised microirradiation with a 405 nm Laser​ (LivePAR Recruitment after laser-induced micro-irradiation)

  • Heme oxygenase-1 protects cells from replication stress. Patryk Chudy, Jakub Kochan, Mateusz Wawro, Phu Nguyen, Monika Gorczyca, Aliaksandra Varanko, Aleksandra Retka, Swati Sweta Ghadei, Emilija Napieralska, Anna Grochot-Przęczek, Krzysztof Szade, Lea-Sophie Berendes, Julien Park, Grzegorz Sokołowski, Qiuliyang Yu, Alicja Jozkowicz, Witold N. Nowak, Wojciech Krzeptowski. Redox Biology. doi.org/10.1016/j.redox.2024.103247

Colocalisation analysis (Colocalisation with the cell membrane)

  • The polybasic region in Gαi proteins: Relevant or not? Insights from Gαi3 research. Beata Rysiewicz, Ewa Błasiak, Marta Dziedzicka-Wasylewska, Agnieszka Polit. Cellular Signalling. doi.org/10.1016/j.cellsig.2024.111138