The Spatial Transcriptomics Laboratory is part of the Biological Structure Imaging and Spatial Transcriptomics Facility, a unit of the Faculty of Biochemistry, Biophysics and Biotechnology (FBBB), whose mission is to provide measurement and analytical services for organisational units of the Jagiellonian University and external entities. The Laboratory offers spatial transcriptomic analyses using the Xenium platform.
The Xenium system is an advanced spatial transcriptomics platform enabling precise mapping of gene expression within the histological context of tissue sections. This technology allows the localisation of thousands of RNA transcripts in situ at single-cell resolution without the need to isolate genetic material.
Labelling with oligonucleotide probes combined with high-resolution microscopic imaging provides data not only on gene expression levels but also on their spatial distribution.
The fully automated system ensures high reproducibility and minimises the risk of operational errors.
Integrated software enables comprehensive data analysis, including cell type identification, cell–cell interaction analysis, and clustering.
Xenium is widely applied in cancer research, neurobiology, immunology, and developmental biology, making it an important tool in precision medicine. By combining molecular analysis with spatial context, the system significantly expands the possibilities for interpreting complex biological processes.
For sample preparation prior to transcriptomic analyses, the Laboratory uses a Biometra TAdvanced 96 SG thermal cycler (Analytik Jena). The Laboratory can also provide access to the thermal cycler for the preparation of single-cell cDNA libraries (Single Cell Gene Expression).
Xenium System (10x Genomics)
- The Xenium system performs cell-level gene expression analysis in prepared tissue samples without disrupting the biological tissue structure.
- Detection is based on fluorescence microscopy using oligonucleotide probes conjugated with fluorescent labels.
- The resulting data enable detailed analysis of cell types present within the tissue specimen, signalling pathways, cell–cell interactions, and more.
- The system integrates transcript localisation, high-resolution imaging, decoding, and data analysis for histological specimens prepared from both fresh frozen (FF) tissues and formalin-fixed paraffin-embedded (FFPE) samples.
- Transcript localisation precision is below 30 nm in the XY plane and below 100 nm along the Z axis, with a pixel size of approximately 0.2 μm/pixel.
- Multimodal cell segmentation links transcript signals to specific cellular locations, converting terabytes of three-dimensional imaging data (3D, XYZ) into biologically meaningful information.
- Dedicated analysis software performs high-throughput computations by converting raw image sensor data into analysis-ready file formats immediately after acquisition.
- The platform is based on in situ sequencing (ISS). Detection efficiency is approximately 1.2–1.5 times higher than that achieved by scRNA-seq. Xenium offers the highest sensitivity among in situ sequencing-based methods and sensitivity comparable to in situ hybridisation (ISH) approaches.
Technical Specifications
- Measurement resolution: transcript localisation precision of XY < 30 nm and Z < 100 nm
- Pixel size: approximately 0.2 μm/pixel
- Number of slides per run: 2 slides
- Throughput (area per time): up to 472 mm² of tissue per run, targeting up to 480 genes in less than 3 days or up to 5,000 genes in less than 6 days
- Total analysable tissue area per run: approximately 472 mm²
- Sample preparation time: 2–3 days, including 4–6 hours of hands-on work
The initial stage of experimental design involves selecting an appropriate panel of fluorescent probes supplied by 10x Genomics. The authorised representative of 10x Genomics in Poland is Analityk Genetyka Unrug Wójtowicz Sp. k.:
- Website: analitykgenetyka.pl
- E-mail: biuro@analitykgenetyka.pl
Biometra TAdvanced 96 SG Thermal Cycler (Analytik Jena)
This thermal cycler is recommended by 10x Genomics for use with samples prepared for the Xenium analyser. Owing to the high instability of RNA, its use for other purposes is limited.
The instrument is equipped with a 96-well silver block (0.2 ml tube capacity), ensuring uniform temperature distribution across the adapter used during sample preparation.
RESERVATIONS
Prior to a planned experiment, users are encouraged to contact the Head of the Laboratory:
- to estimate the time required to complete the study and the overall project costs;
- to verify equipment availability.
Following preliminary arrangements, reservations for the Xenium analyser should be made via e-mail at: wbbib.bioobrazowanie@uj.edu.pl
The reservation request should include:
- number of samples (slides);
- tissue preparation method (FF or FFPE);
- measurement type (V1 or Prime);
- scanned area (up to 2.35 cm² per slide).
Based on this information, the sample preparation time and analysis duration will be estimated.
PRICING
The costs of sample preparation (slides containing tissue sections) and analysis are calculated individually for each project.
Enquiries should be sent to: wbbib.bioobrazowanie@uj.edu.pl
Services are available to FBBB staff, employees of other Jagiellonian University units, and external organisations.
EXAMPLE COST ESTIMATION FOR JAGIELLONIAN UNIVERSITY UNITS
Preparation of Tissue Samples on Specialised Slides for Xenium Spatial Transcriptomics Analysis
- Consumables: approximately PLN 488.24 (gross)
- Instrument and Operator Time: for two specimens (sample preparation, ligation, amplification: 10 hours; hybridisation: 16–24 hours):
- PLN 52 net/hour (FBBB JU and other JU faculties without overhead costs)
- PLN 148.50 net/hour (other JU faculties including overhead costs)
Xenium Analyser Setup and Measurement for Two Specimens
Consumables:
- Approximately PLN 963.41 gross for V1 analysis
- Approximately PLN 1,570.55 gross for Prime analysis
Instrument and Operator Time
V1 Analysis:
- PLN 177 net/hour (FBBB staff and other JU faculties without overhead costs)
- PLN 380 net/hour (other JU faculties including overhead costs)
Prime Analysis:
- PLN 133.05 net/hour (other JU faculties without overhead costs)
- PLN 154.06 net/hour (other JU faculties including overhead costs)
- PLN 70/hour (FBBB staff, in accordance with the decision of the Dean of the Faculty).
ACKNOWLEDGEMENTS
When publishing results obtained using the Spatial Transcriptomics Laboratory, authors should include an acknowledgement of the Xenium platform, for example:
"In situ transcriptomic studies (Xenium) were performed at the Spatial Transcriptomics Laboratory, which serves as a core facility at the Faculty of Biochemistry, Biophysics and Biotechnology, Jagiellonian University."
Such acknowledgements support the continued funding and maintenance of advanced analytical technologies for the scientific community.
Please send publication details and DOI numbers to: wbbib.bioobrazowanie@uj.edu.pl
DATA MANAGEMENT
Raw data generated during measurements, together with processed datasets where applicable, are stored in an encrypted cloud storage service for a period of three months.
Data are shared with users via secure access links.
Transfer of data using USB storage devices is not permitted.
Files stored in the cloud constitute the only copy retained by the Laboratory. Deletion of cloud-stored files results in the permanent removal of the corresponding data from the local hard drive connected to the Xenium analyser.
The Laboratory encourages users to deposit datasets in specialised research repositories such as IDR and the BioImage Archive. Recommendations concerning the management of in situ transcriptomics data have been published in Cell Genomics.
The Laboratory also provides support with the preparation of Data Management Plans (DMPs) for current and prospective users.
Enquiries regarding DMP support should be directed to: wbbib.bioobrazowanie@uj.edu.pl
Coordinator: Dr Beata Rysiewicz
- Telephone: +48 538 629 891
- E-mail: wbbib.bioobrazowanie@uj.edu.pl
- Office: room 1.01.3 (Level 01)